Issue: Fan Alarm observed on Juniper J Series Router- Juniper J4350.
We have observed alarms of Fan at router chassis not CPU, sometimes Fan 0 went to "check" state and Fan 1 spin at high spineed and vice-versa.
Troubleshooting Steps:
We have checked RSI(request Support Information) and show log command outputs from router.
We have observed alarms of Fan at router chassis not CPU, sometimes Fan 0 went to "check" state and Fan 1 spin at high spineed and vice-versa.
Troubleshooting Steps:
We have checked RSI(request Support Information) and show log command outputs from router.
After analysis of RSI provided, The fan failure messages and it
gets cleared as well. as per PR797706 <https://gnats.juniper.net/web/default/797706>
this has been reported as a bug and suggests an upgrade to 11.4R5-S1 11.4R6
12.1R4 12.1X44-D10.
In order to upgrade to any version greater than 10.4, the
flash and RAM has to be 1GB.
Now you have 1Gb of RAM
root@J4350> show chassis routing-engine
DRAM 1024 MB
but only 512Mb of Flash, you need to upgrade to 1Gb
root@haryana_PE2_J4350> show system storage
Filesystem
Size Used Avail
Capacity Mounted on
/dev/ad0s1a
432M 104M 323M 24%
/
The following is the link which would help you understand
the same: